The L15-5 linear array transducer, with a center frequency of 10MHz, is designed for Vascular, Small Parts and deep MSK imaging.
Center Frequency | 10.0 MHz |
Bandwidth | 85% |
Number of Elements | 192 |
Element Spacing | 0.20 mm |
Elevation Focus | 18 mm |
Elevation Aperture | 3.25 mm |
Maximum AC Voltage | 120V |
Bias DC Input | +3.3V~+10.5V |
The L30-14 linear array transducer which is centered at 22MHz can be used primarily for Neonatal, Pediatric, and MSK applications.
Center Frequency | 22.0 MHz |
Bandwidth | 70% |
Number of Elements | 256 |
Element Spacing | 0.082 mm |
Elevation Focus | 10.8 mm |
Elevation Aperture | 2.25 mm |
Maximum AC Voltage | 120V |
Bias DC Input | +3.3V~+10.5V |
The L22-8 linear array transducer is the workhorse for MSK and Small Parts Imaging. Centered at 15MHz, this transducer has better spatial resolution with equal penetration when compared with PZT transducers.
Image GalleryCenter Frequency | 15.0 MHz |
Bandwidth | 80% |
Number of Elements | 256 |
Element Spacing | 0.108 mm |
Elevation Focus | 15 mm |
Elevation Aperture | 2.5 mm |
Maximum AC Voltage | 120V |
Bias DC Input | +3.3V~+10.5V |
The L38-22 with a center frequency of 30MHz allows for true superficial imaging in the emerging applications of Dermatology. Additional applications include tendons, nerves, and joints of the Hands, Wrist, and Feet.
Image GalleryCenter Frequency | 30.0 MHz |
Bandwidth | 60% |
Number of Elements | 256 |
Element Spacing | 0.069 mm |
Elevation Focus | 8.0 mm |
Elevation Aperture | 1.8 mm |
Maximum AC Voltage | 120V |
Bias DC Input | +3.3V~+10.5V |
A 1D transducer array has single elements with fixed size and focus in the elevational dimension. A SiliconMatrixTM Array has multiple elements in both the azimuthal and elevational dimensions enabling a variable aperture size with multiple focal points to generate a narrow elevation beam throughout the entire imaging field resulting in unparalled image quality to depth.
Center Frequency | 8.0-10.0 MHz |
Bandwidth | 90-110% |
Number of Elements | 192 |
Number of Sub-elements | 3 |
Element Spacing | 0.21 mm |
Elevation Focus | 30.0 mm |
Elevation Aperture | 3.0+1.5×2 mm |
Maximum AC Voltage | 120V |
Bias DC Input | +3.3V~+10.5V |
Category | Central Frequency | Elements | Application | Main Products |
Linear Transducers | 7.5-30MHz | 128-384E | Neonatology & Pediatrics Musculoskeletal Dermatology Small Parts Vascular Breast ... Intraoperative Laparoscopy Photoacoustic imaging ... | L38-22 |
L30-14 | ||||
L22-8 | ||||
L15-5 | ||||
Matrix Transducers | 7.5-15MHz | 128-256E | M17-4 |